Distance measurement
Width, Thickness, Height measurement
Thickness & width gauges
Laser Scanners
Velocity meters & length measurement
laser-captor (Hi Temp)
Laser Applications
Laser Measurement Tables
Hot Metal Detectors
Low temperature metal and aluminum detectors
Proximity & Inductive switches
Loop scanner and detector
Flowmeters and Flow Switches
Flowmeters and Flow Switches for air & gaseous media
L-shaped angle sensors & thru beam
Temperature Sensors and Switches
IR Thermometers
Proximity & Level sensors
Intrinsically Safe & Explosion Proof
Adjustable Set Point Controllers
Application Examples
Digital Panel Meters
Vision System
Applications for Captor Products
Page 1/7
Environmental Cooling System (ECS)

Environmental Cooling System (ECS)

Monitoring air flow in aircraft ECS is critical to ensure the adequate cooling of critical areas, such as, the avionics manifold. vent-captor is typically installed in the secondary air supply lines that lead to the avionics manifold, cargo areas and main cabin. The solid state output can be set over a wide flow range from 0.25-100 SPPS.

Click on the picture to enlarge.

Lube Oil Flow Detection in Compressor Lines

Lube Oil Flow Detection in Compressor Lines

weber Sensors has a long history of detecting lube oil low flows in the steel industry. Many applications exist outside this industry like the monitoring of critical oil lubrication to large compressor systems.weber's in-line model 4320.1 flow-captor, is the best choice for this requirement. Euro-style rack mounted electronics is also available, if desired.

Click on the picture to enlarge.

Laser Cooling Systems

Laser Cooling Systems

weber's non-intrusive flow-captor is ideally suited for monitoring the loss of cooling fluid in laser cooling systems. Locate the flow captor downstream of the housing containing the laser chamber and flash tube. The flow-captor will alarm at a pre-specified flow set point & indicate temperature, if desired, for over temperature protection.

Click on the picture to enlarge.

Weapon Cooling Systems

Weapon Cooling Systems

In weapon systems that are liquid cooled with fresh or salt water, a flow sensor is used to detect a loss of cooling water in the event a filter, or valve becomes clogged. Model 204/4050.31 flow-captor, is well suited & is available in exotic alloys suitable for salt water service.

Click on the picture to enlarge.

Oil Cooling Systems

Oil Cooling Systems

Model 4204/4050.31 flow-captor monitors critical transformer cooling oil flow rate, and temperature on high speed train. flow-captor is ideal because of its dual output capability, permitting the monitoring of flow rate and temperature of the dielectric heat transfer cooling oil.

Click on the picture to enlarge.

Engine APU Water Cooling Systems

Engine APU Water Cooling Systems

flow-captor detects a critical no-flow condition immediately after a fan belt fails on the 4.108 engine APU. Loss of drive to the water pump will cause a no flow condition, which is detected by the flow-captor.

Click on the picture to enlarge.

 
   
Gordy’s Sensors • 5772 Smaller Rd, Johnstown, OH 43031
Phone: (740) 967-2283 • Fax: (740) 967-2855
www.gordyssensors.com or
sales@gordyssensors.com